|
|
|
Anesthesia Needles :: ...................... |
|
JC3087 : ANESTHESIA NEEDLES
JC-3087 : 20G - 6"
BAILEY FONTONAL SECURITY STOP NEEDLE : Has security stop positioned 1/2" from point. Fitted with standard female luer hub, sharp pointed cannula and a fitted stylet with matched beveled point.
|
|
JC3089 : PUDENAL PARACERVICAL AND PARASYMPATHETIC NERVE BLOCK NEEDLE
JC-3089 : 20G-6"
FREEMAN NEEDLE : This three piece needle set includes a 17G guide cannula with bulbous tip 5" long and 20G 6" short bevel needle, which when passed through the guide extends approximately 5/8" beyond the bulbous tip. The bulbous tip J
prevents trauma during injection to the surrounding tissue. This set is designed to relieve labor pain of uterine origin.
|
|
JC3090 : TROPICAL ANESTHESIA
JC-3090 : Overall 6"
CORDNER LARYNGEAL SPRAY : Has a knurled female luer hub and bulbous tip at end of curved flexible tube. Bulbous tip has an axial hole plus four peripheral holes which readily allows for a 3600 topical anesthesia spray.
|
|
JC3031 : CAUDAL ANESTHESIA, CONTINOUS
JC-3031 : 18 G TW-3" & 3.5"
JC-3033 : 17G TW-3",3.5" & 7"
JC-3035 : 16G TW-3",3.5" & 7"
JC-3037 : 14G TW-3",3.5" & 7"
JC-3041 : 18G TW-3" & 3.5"
JC-3043 : 17G TW-3",3.5" & 7"
JC-3045 : 16G TW-3",3.5" & 7"
JC-3047 : 14G TW-3",3.5" & 7"
TUOHY NEEDLE : Thin wall needle with Needle Lock Hub and Fitted Stylet with matched beveled point. They have Deflected (HUBER) points with heel of bevel dulled to prevent tubing from being cut. Tubing may be directed into sub arachnoid or epidural space either cephelad or cauded.
|
|
JC3051 : EPIDURAL, CONTINOUS
JC-3051 : 18G TW-3"
JC-3053 : 17G TW-3"
JC-3055 : 16G TW-3"
JC-3057 : 18G TW-3"
JC-3059 : 17G TW-3"
JC-3061 : 16G TW-3"
TUOHY (WEISS TYPE) NEEDLE : Like standard Tuohy, but with a gripping shield, used in continuous epidural anesthesia. Tubing can easily be introduced.
|
|
JC3071 : INTRAVENOUS ANESTHESIA
JC-3071 : 15G TW-1.5"
JC-3073 : 14G TW-1.5"
JC-3075 : 13G TW-1.5"
JC-3077 : 12G TW-1.5"
INTRAVENOUS AND ARTERIAL THIN WALL SHORT BEVEL NEEDLES : Designed for use in intravenous and intra arterial applications as well as nerve block procedures, these needles feature an 180 point bevel. The thin wall needles are suitable for use with plastic tubing.
|
|
JC3081 : LOCAL ANESTHESIA
JC-3081 : 22G-1.5",2",2.5",3",4",5",6"
JC-3083 : 20G-1.5",2",2.5",3",4",5",6"
SECURITY STOP (REGIONAL BLOCK) NEEDLES : Have a female luer hub with sharp pointed cannula. A security bead is affixed one eighth inch from the hub to help in withdrawal in case of accidental breakage. The regular bevel is ideal for infiltration anesthesia. The short bevel design provides optimum feel upon insertion into subcutaneous tissues, facia, ligaments and sheath surrounding the nerve bundle. Also available with deflected point for special procedures.
|
|
|